VG meter

pump401

The instrument used to measure viscosity and gel strength of drilling mud. The direct-indicating viscometer is a rotational cylinder and bob instrument, also known as a V-G meter. Two speeds of rotation, 300 and 600 rpm, are available in all instruments, but some are 6- or variable-speed. It is called "direct-indicating" because at a given speed, the dial reading is a true centipoise viscosity.

For example, at 300 rpm, the dial reading (511 sec-1) is a true viscosity. Bingham plastic rheological parameters are easily calculated from direct-indicating viscometer readings:

  • PV (in units of cP) = 600 dial - 300 dial
  • YP (in units of lbm/100 ft2) = 300 dial - PV
  • Gel strength is also directly read as dial readings in oilfield units of lbm/100 ft2.

 

In order to find out more about VG meter, contact us with the subject of "VG meter".